Overview

Getting high quality images is easy with the Fluke TiX560. This professional grade thermal camera spots even the most minor differences in temperature, helping you to work faster, more efficiently and get the results you need, every time.

The TiX560 has an extremely high resolution thermal core which produces images of 320 x 240 pixel quality. These images are shown directly on the TiX560's built-in 5.7" fast response touchscreen, or can be downloaded onto a PC for further analysis using Fluke's software.

An upgraded version of the TiX520, this camera comes with additional functions. The main difference is an increase in the overall temperature measurement range from -850°C to +1200°C but it also comes with digital zoom functions (2x, 4x and 8x) plus Fluke's on-board SuperResolution technology that can improve the quality of captured images by up to four times.

This thermal camera is compatible with Fluke Connect certified testing tools, allowing wireless data to be transmitted to other compatible Fluke products or even smartphones which are running the Fluke Connect app.

Fluke TiX560 Thermal Camera Key Features

  • Largest-size touchscreen currently on the market - 5.7" fast response for easy adjustments and image management
  • 180° articulating lens - move the lens as needed to get the best possible image in awkward applications
  • Premium image quality - standard resolution of 320 x 240 pixels
  • Use Fluke's SuperResolution mode (available in the software and on the camera) to increase image quality by up to 4x
  • LaserSharp Auto Focus - precise laser technology automatically focuses on a target with pinpoint accuracy
  • Integrated laser distance meter - calculates and displays the exact distance an image was captured at from the camera
  • IR-Fusion technology - active blending of digital and thermal images for enhanced detail
  • Continuous level and span adjustment
  • Filter mode allows adjustments to thermal sensitivity from 50mK to 30mK to locate finer temperature differences
  • Post capture image editing - adjust emissivity, background temperature, transmissivity, palettes, colour alarms, IR fusion, enable/disable markers
  • Fluke Connect enabled - wireless interfacing with enabled Fluke testing tools and selected smartphones
  • 5MP industrial performance digital camera built in
  • Wide temperature measurements range: -20 to +1200°C (-4 to +1562°F)
  • Selectable colour palettes - 8 standard modes and 8 ultra contrast options
  • Optional lenses (sold separately) - swap out the standard lens for a wide angle or telephoto lens
  • Light, ergonomic design for easy capturing

What's Included?

  • Fluke TiX560 Thermal Camera
  • Standard Infrared Lens
  • AC Power Supply with Battery Pack Charger (Incl. Universal AC Adapters)
  • 2 x Lithium Ion Smart Battery Packs
  • USB Cable
  • HDMI Video Cable
  • Bluetooth Headset
  • Hard Carrying Case
  • Adjustable Neck/Hand Strap
  • Flash Drive with SmartView Software and User Manuals
  • Warranty Registration Card
  • Manufacturer's Calibration Certificate
Features

Need more information? Find it in the full technical specification and reviews.

  • Select Lens

    24° Lens

  • Sensitivity

    The Fluke TiX560 Thermal Camera has a thermal sensitivity of 30mK NETD. A lower mK value means a more accurate thermal camera.

Technical Specification

Fluke TiX Technical Specifications

FeatureTiX560TiX520
IFOV with Standard Lens (Spatial Resolution) 1.31mRad
Detector Resolution 320 x 240 (76,800 pixels)
Field of View 24°H x 17°V
Minimum Focus Distance 15cm (approx 6")
IFOV with Optional Telephoto Lens 0.65mRad
Field of View 12°H x 9°V
Minimum Focus Distance 45cm (approx 18")
IFOV with Optional Wide Angle Lens 2.62mrad
Field of View 46°H x 34°V
Minimum Focus Distance 15cm (approx 6")
Other Features    
SuperResolution On camera and in software In software
Image Sharpening Yes No
LaserSharp Auto Focus Yes, for consistently in-focus images
Laser Distance Meter Yes Yes
Advanced Manual Focus Yes Yes
Streaming Video (Remote Display) Via USB or WiFi
Touchscreen Display (Capacititive) 14.4cm (5.7") diagonal landscape colour VGA (640 x 480) LCD with backlight
Wireless Connectivity    
Wireless Compatibility PC, iPhone, iPad (iOS 4 and later), Android 4.3 and up, and WiFi to LAN  
Fluke Connect App Compatible? Yes
Fluke Connect Tool Compatible Yes. Connects wirelessly to Fluke Connect enabled tools
IR Fusion Technology Yes
AutoBlend Mode Yes
Picture-In-Picture (PIP) Yes
Continuous AutoBlend Set AutoBlend level across continuum No
Design Rotatable (articulating) lens >180°
Thermal Sensitivity (NETD) ≤0.045°C at 30°C target temperature (45mK)
≤0.05°C at 30°C target temperature (50mK)
Filter Mode (NETD Improvement) ≤0.03°C at 30°C target temperature (30mK)
≤0.04°C at 30°C target temperature (40mK)
Level and Span    
Touchscreen Adjustable Level/Span Yes
Fast Auto Toggle Between Manual/Auto Modes Yes
Fast Auto Rescale In Manual Mode Yes
Minimum Span (In Manual Mode) 2.0°C (3.6°F)
Minimum Span (In Auto Mode) 3.0°C (5.4°F)
Built-in Digital Camera (Visible Light) 5 megapixel industrial performance
Frame Rate 60Hz or 9Hz versions
Laser Pointer Yes
LED Light (Torch) Yes
Digital Zoom 2x, 4x, 8x 2x, 4x
Data Storage/Image Capturing    
Memory Options Removable micro SD memory card, on-board flash memory, save-to-USB compatibility, direct download via USB to PC connection
Post-Capture Image Editing (On Camera) Yes
Advanced Text Annotation Yes including standard shortcuts plus user-programmable options
File Formats Non-radiometric (.bmp) or (.jpeg) or fully radiometric (.is2); no analysis software required for non-radiometric (.bmp, .jpg and .avi) files
Memory Review Thumbnail view navigation and review selection
Software SmartView® software, Fluke Connect™ (where available), and SmartView® Mobile App—full analysis and reporting software
Export File Formats with SmartView Software BMP, DIB, GIF, JPE, JFIF, JPEG, JPG, PNG, TIF, and TIFF
Voice Annotations 60 seconds maximum recording time per image; reviewable playback on camera; Bluetooth headset provided*
IR PhotoNotes Yes
Text Annotations Yes
Video Recording Standard and radiometric
Video File Formats Non-radiometric (MPEG - encoded .AVI) and fully radiometric (.IS3)
Remote Control and Operation Yes No
Auto Capture (Temperature and Interval) Yes
Battery    
Type 2 x lithium ion smart battery packs
Battery Life 3 hours continuous use
Battery Charge Time 2.5 hours to full charge
Battery Charging System 2 bay battery charger or in-camera charging. Optional 12V automotive charging adapter
AC Operation With included power supply (100V AC to 240V AC, 50/60Hz)
Power Saving User-selectable sleep and power off modes
Temperature Measurement    
Measurement Range (Not Calibrated Below -10°C) -20 to +1200°C (-4 to +2192°F) -20 to +850°C (-4 to 1562°F)
Accuracy ±2°C or 2% (at 25°C nominal, whichever is greater)
On-Screen Emissivity Correction Yes (both value and table)
On-Screen Reflected Background Temperature Compensation Yes
On-Screen Transmission Correction Yes
Colour Palettes    
Standard 8: Ironbow, Blue-Red, High Contrast, Amber, Amber Inverted, Hot Metal, Greyscale, Greyscale Inverted
Ultra Contrast Palettes 8: Ironbow Ultra, Blue-Red Ultra, High Contrast Ultra, Amber Ultra, Amber Inverted Ultra, Hot Metal Ultra, Greyscale Ultra, Greyscale Inverted Ultra
General Specifications    
Colour Alarms (Temperature Alarms) High temperature and low temperature
Infrared Spectral Band 7.5μm to 14μm (long wave)
Operating Temperature -10 to +50°C (14 to 122°F)
Storage Temperature -20 to +50°C (-4 to 122°F) without batteries
Relative Humidity 10 to 95% non-condensing
Center-Point Temperature Measurement Yes
Spot Temperature Hot and cold spot markers
User-Defineable Spot Markers 3x
Centre Box Expandable/contractible measurement box with MIN/MAX/AVG temperature
Safety IEC 61010-1: overvoltage category II, Pollution Degree 2
Electromagnetic Compatibility IEC 61326-1: basic EM environment
CISPR11, Group 1, Class A
Australian RCM IE 61326-1
US FCC CFR 47, Part 15 Subpart B
Vibration 0.03g2/Hz (3.8grms), 2.5g IEC 68-2-6
Shock 25g, IEC 68-2-29
Drop Engineered to withstand drops of 1m (3.3) with standard lens
Size (H x W x L) 27.3 x 15.9 x 9.7cm (10.8 x 6.3 x 3.8 inches)
Weight (Battery Included) 1.54kg (3.4lbs)
Enclosure Rating IEC 60529: IP54 (protected against dust, limited ingress; protection against water spray from all directions)
Warranty 2 years (standard) with extended available
Recommended Calibration Cycle 2 years (assumes normal operation and normal aging)
Reviews

Why not leave a review for the Fluke TiX560 Thermal Camera?

Great quality reviews both help out fellow customers and help us to improve the service we give to you, so we'd really appreciate you taking the time to leave your thoughts on this item.

No reviews have been found

Write Your Own Review

You're reviewing: Fluke TiX560 Thermal Camera

How do you rate this product? *

  1 star 2 stars 3 stars 4 stars 5 stars
Price
Value
Quality