The Fluke ii1030 Acoustic Imager locates and quantifies compressed air, gas and vacuum leaks, and verifies air tightness. SoundSight technology uses 202 digital MEMS microphones to display ultrasonic sound sources over a visible image, with detection from more than 100 m away, depending on ambient conditions.
LeakQ estimates leak rates and energy costs to prioritise repairs, while Beacon Mode, with the optional SB140 SoundBeacon, identifies sealing defects. A 7-inch anti-glare touchscreen, 13 MP camera and SoundMap overlay support inspection documentation, image and video capture, and on-device reporting.
Available with or without 1 or 3 years of Fluke Premium Care (FPC).
| ii1030 | ii1050 | |
|---|---|---|
| Sensors | ||
| MEM (Microphones) | 202 | 202 |
| Frequency Band | 2 kHz to 64 kHz | 2 kHz to 100 kHz |
| Detection Range1 | 0.5 to > 100 meters (1.6 to > 393 feet) |
0.5 to > 150 meters (1.6 to > 492 feet) |
| Field of View (FOV) (Typical) | 64°x 48° | |
| Nominal Frame Rate | 25 FPS | |
| Built-in Digital Camera (Visible Light) | ||
| Field of View (FOV) (Typical) | 64° x 48° | |
| Focus | 50 cm to infinity (20 inch) |
|
| Zoom | 3 x digital zoom | |
| Resolution | 13 MP | |
| Display | ||
| Size | 7" Anti-Glare LCD with backlight, sunlight readable | |
| Resolution | 1280 x 800 (1,024,000 pixels) | |
| Touchscreen | Capacitive | |
| Acoustic Image | SoundMap acoustic imaging overlay | |
| Image Storage | ||
| Storage Capacity | 110 GB | |
| Image Format | Blended visual and SoundMap™.JPG | |
| Video Format | Blended visual and SoundMap™.MP4 | |
| Video Length | Up to 5 minutes | |
| Digital Export | USB-C for data transfer | |
| Acoustic | ||
| Measurement Range (typical) | 20 kHz: -10.4 ~ 122 dB SPL 25 kHz:-24.7~ 122 dB SPL 31.5 kHz:-13~ 122 dB SPL 40 kHz: -10.7~ 122 dB SPL 50 kHz: 8~ 122 dB SPL |
|
| Auto Max/Min dB Gain | Auto or user-selectable max dB | |
| Frequency Band Selection | User-selectable through user-made presets or manual entry | |
| Capture Mode | ||
| Photo | Yes | Yes |
| Video | Yes | Yes |
| LeakQ | Leak size scale, rate and cost estimation | Leak size scale, rate and cost estimation |
| PDQ Mode | - | Yes |
| MecQ | - | Yes |
| Beacon | Yes, works with Fluke SB140 SoundBeacon™ for airtightness detection. | |
| Thermal | Yes, works with TC03A | |
| Battery | ||
| Battery | Rechargeable and field-replaceable Li-ion battery | |
| Battery Life | >7 hours (2 x 3.5hrs) | |
| Battery Charging Time | <3 hours | |
| Battery Charging System | Internal (USB-C) | |
| Software | ||
| Ease of Use | Intuitive user interface | |
| Acoustics: Show dB Scale | On/Off | |
| Acoustics: Min/Max dB | Max dB/Auto | |
| Acoustics: Profiles | Preset capture profiles | |
| Acoustics: High Frequency | - | Yes |
| Acoustics: Multiple Sources | Multi Source | |
| Palette: Colours | 3: Grayscale, Ironbow, and Blue-Red | |
| Palette: Overly Transparent | Yes: 1-100 % | |
| Grayscale Mode | Yes | |
| Trend Graphs | Frequency and dB scale | |
| Leak Values | Leak costs, Leak volume, LeakQ TM scale (1-10) | |
| Annotation | Asset name; Asset ID; Asset type; Leak type; Gas type; Pressure | |
| Photo Notes | Up to 4 photo notes for reference | |
| Asset Inspection Status | As left', 'As found', 'Undetermined' | |
| Asset ID | Text input and automatic QR code-based asset ID identification | |
| Actions Annotation | Action requirement, priority, and notes | |
| On-Device Reporting | Support (PDQ, LeakQ, PDQ+Ti, LeakQ+Ti, Ti mode) | |
| General Specification | ||
| Tripod Holder / Connector | Yes: 1/4"-20 | |
| USB | 2 x USB-C | |
| Wireless | Wi-Fi | |
| Operating Temperature | -10 to 45 °C (14 to 113 °F) |
|
| Storage Temperature | -20 to 70 °C (-4 °F To 158 °F) without batteries installed |
|
| Operating Altitude | Up to 2000 m | Up to 2000 m |
| Storage Altitude | Up to 12000 m | Up to 12000 m |
| Relative Humidity | 10 to 95 % RH, non-condensing | |
| Size (H x W x L) | 235 × 154 × 46 mm (9.25 × 6.06 × 1.81 inches) |
|
| Weight (Battery Included) | 1,2 kg (2.6 pounds) |
|
| Ingress Protection (IP) | IP54 | |
| Warranty | 2 year | |
| Fluke Premium Care | Premium Care Standard2 | |
| Self-Diagnostic Notification | Array health test to identify when the microphone array needs attention | |
| Supported Languages | Arabic, Dutch, English, Finnish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Simplified Chinese, Spanish, Swedish, Traditional Chinese | |
| Safety & Environmental | ||
| RoHS Compliant | Yes | |
| General Safety | IEC 61010-1: Pollution degree 2 | |
| Electromagnetic Compatibility (EMC) International | IEC 61326-1: Industrial Electromagnetic Environment, CISPR 11: Group 1, Class A | |
| Korea (KCC) | Class A Equipment (Industrial Broadcasting and Communication) | |
| USA (FCC) | 47 CFR 15 subpart | |
| Radio Equipment Directive (2014/53/EU) (RED) | Yes | Yes |
| ¹Depending on ambient conditions | ||
| ²Subject to regional availability (www.fluke.com/premiumcare) | ||
| 3 Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments. |
||
| 4. Device meets requirements for industrial electromagnetic wave equipment, and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes. | ||