The Fluke ii1050 Acoustic Imager locates compressed air, gas and vacuum leaks, detects partial discharge, identifies mechanical issues and verifies air tightness. SoundSight™ technology uses a 202-microphone array to pinpoint abnormal sound sources across a 2 kHz to 100 kHz frequency range, with detection up to 150 m away, depending on ambient conditions.
LeakQ™ estimates leak rates and energy costs, PDQ Mode™ analyses partial discharge, and MecQ™ identifies mechanical issues such as bearing defects, friction and turbulence. Beacon Mode supports air-tightness inspections with the optional SB140 SoundBeacon™.
The ii1050 features a 7-inch anti-glare touchscreen, 13 MP camera, 128 GB storage and on-device reporting. Selected configurations include the TC03A iSee™ Thermal Camera Attachment for thermal, acoustic and visible-light inspection.
Available as a standard acoustic imager or in thermal and SoundBeacon™ kits, with selected variants offering 1 or 3 years of Fluke Premium Care (FPC).
| ii1030 | ii1050 | |
|---|---|---|
| Sensors | ||
| MEM (Microphones) | 202 | 202 |
| Frequency Band | 2 kHz to 64 kHz | 2 kHz to 100 kHz |
| Detection Range1 | 0.5 to > 100 meters (1.6 to > 393 feet) |
0.5 to > 150 meters (1.6 to > 492 feet) |
| Field of View (FOV) (Typical) | 64°x 48° | |
| Nominal Frame Rate | 25 FPS | |
| Built-in Digital Camera (Visible Light) | ||
| Field of View (FOV) (Typical) | 64° x 48° | |
| Focus | 50 cm to infinity (20 inch) |
|
| Zoom | 3 x digital zoom | |
| Resolution | 13 MP | |
| Display | ||
| Size | 7" Anti-Glare LCD with backlight, sunlight readable | |
| Resolution | 1280 x 800 (1,024,000 pixels) | |
| Touchscreen | Capacitive | |
| Acoustic Image | SoundMap acoustic imaging overlay | |
| Image Storage | ||
| Storage Capacity | 110 GB | |
| Image Format | Blended visual and SoundMap™.JPG | |
| Video Format | Blended visual and SoundMap™.MP4 | |
| Video Length | Up to 5 minutes | |
| Digital Export | USB-C for data transfer | |
| Acoustic | ||
| Measurement Range (typical) | 20 kHz: -10.4 ~ 122 dB SPL 25 kHz:-24.7~ 122 dB SPL 31.5 kHz:-13~ 122 dB SPL 40 kHz: -10.7~ 122 dB SPL 50 kHz: 8~ 122 dB SPL |
|
| Auto Max/Min dB Gain | Auto or user-selectable max dB | |
| Frequency Band Selection | User-selectable through user-made presets or manual entry | |
| Capture Mode | ||
| Photo | Yes | Yes |
| Video | Yes | Yes |
| LeakQ | Leak size scale, rate and cost estimation | Leak size scale, rate and cost estimation |
| PDQ Mode | - | Yes |
| MecQ | - | Yes |
| Beacon | Yes, works with Fluke SB140 SoundBeacon™ for airtightness detection. | |
| Thermal | Yes, works with TC03A | |
| Battery | ||
| Battery | Rechargeable and field-replaceable Li-ion battery | |
| Battery Life | >7 hours (2 x 3.5hrs) | |
| Battery Charging Time | <3 hours | |
| Battery Charging System | Internal (USB-C) | |
| Software | ||
| Ease of Use | Intuitive user interface | |
| Acoustics: Show dB Scale | On/Off | |
| Acoustics: Min/Max dB | Max dB/Auto | |
| Acoustics: Profiles | Preset capture profiles | |
| Acoustics: High Frequency | - | Yes |
| Acoustics: Multiple Sources | Multi Source | |
| Palette: Colours | 3: Grayscale, Ironbow, and Blue-Red | |
| Palette: Overly Transparent | Yes: 1-100 % | |
| Grayscale Mode | Yes | |
| Trend Graphs | Frequency and dB scale | |
| Leak Values | Leak costs, Leak volume, LeakQ TM scale (1-10) | |
| Annotation | Asset name; Asset ID; Asset type; Leak type; Gas type; Pressure | |
| Photo Notes | Up to 4 photo notes for reference | |
| Asset Inspection Status | As left', 'As found', 'Undetermined' | |
| Asset ID | Text input and automatic QR code-based asset ID identification | |
| Actions Annotation | Action requirement, priority, and notes | |
| On-Device Reporting | Support (PDQ, LeakQ, PDQ+Ti, LeakQ+Ti, Ti mode) | |
| General Specification | ||
| Tripod Holder / Connector | Yes: 1/4"-20 | |
| USB | 2 x USB-C | |
| Wireless | Wi-Fi | |
| Operating Temperature | -10 to 45 °C (14 to 113 °F) |
|
| Storage Temperature | -20 to 70 °C (-4 °F To 158 °F) without batteries installed |
|
| Operating Altitude | Up to 2000 m | Up to 2000 m |
| Storage Altitude | Up to 12000 m | Up to 12000 m |
| Relative Humidity | 10 to 95 % RH, non-condensing | |
| Size (H x W x L) | 235 × 154 × 46 mm (9.25 × 6.06 × 1.81 inches) |
|
| Weight (Battery Included) | 1,2 kg (2.6 pounds) |
|
| Ingress Protection (IP) | IP54 | |
| Warranty | 2 year | |
| Fluke Premium Care | Premium Care Standard2 | |
| Self-Diagnostic Notification | Array health test to identify when the microphone array needs attention | |
| Supported Languages | Arabic, Dutch, English, Finnish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Simplified Chinese, Spanish, Swedish, Traditional Chinese | |
| Safety & Environmental | ||
| RoHS Compliant | Yes | |
| General Safety | IEC 61010-1: Pollution degree 2 | |
| Electromagnetic Compatibility (EMC) International | IEC 61326-1: Industrial Electromagnetic Environment, CISPR 11: Group 1, Class A | |
| Korea (KCC) | Class A Equipment (Industrial Broadcasting and Communication) | |
| USA (FCC) | 47 CFR 15 subpart | |
| Radio Equipment Directive (2014/53/EU) (RED) | Yes | Yes |
| ¹Depending on ambient conditions | ||
| ²Subject to regional availability (www.fluke.com/premiumcare) | ||
| 3 Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments. |
||
| 4. Device meets requirements for industrial electromagnetic wave equipment, and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes. | ||